STRUT BUILDING SURVEYORS · SURVEY REPORT EXAMPLE

Thatched & Listed Building Survey – Interactive Example

Explore a specialist survey of a Grade II listed late seventeenth-century cottage in Old Malton. This edited example demonstrates how Strut combines building pathology, drone inspection, heritage assessment and specialist thatching expertise to develop a practical conservation and capital maintenance strategy.

Explore the example report ↓
Grade II listed Thatch Cottage in Old Malton viewed during drone survey
LISTED & THATCHED BUILDING SURVEY · OLD MALTON

Historic Building Survey

Thatch Cottage · Grade II Listed · June 2026

Specialist thatch assessment. Drone inspection. Conservation repairs. Long-term capital planning.

Open report ↓
01 / INSPECTION OVERVIEW

Survey at a glance

Thatch Cottage is a Grade II listed historic dwelling believed to date from the late seventeenth century. The building is principally constructed from coursed sandstone rubble masonry beneath a traditional water-reed thatched roof and incorporates an attached former agricultural byre together with ancillary outbuildings.

Inspection items 40 Building fabric & services
Indicative repair budget £117.5k–£164.5k Original report · excluding VAT
Inspection date 7 Jun 2026 Old Malton, North Yorkshire
Multi-disciplinary inspection

The inspection was undertaken by Strut with an experienced Master Thatcher in attendance. High-level roof areas were additionally inspected using drone imagery.

02 / PROFESSIONAL OPINION

Executive summary

The property is a highly attractive historic dwelling retaining significant traditional fabric. Internally, the accommodation was generally well presented and the accessible structure showed no significant evidence of ongoing instability at the inspection date.

The principal liability is the condition of the thatched roof. The water-reed covering displays advanced weathering, moss growth, localised thinning and gullying, while the traditional straw ridge has deteriorated significantly. Evidence of localised moisture penetration was also identified.

Following specialist assessment, the roof was considered beyond the stage at which localised patch repairs would represent a practical long-term solution. Comprehensive re-thatching should therefore be anticipated.

Importantly, the proposed project extends beyond replacement of the visible thatch. Removal of the existing covering will expose the concealed roof structure, battens and interfaces for the first time, creating both an opportunity for proper conservation repair and a risk of additional concealed expenditure.

Major short-term capital project

The existing thatch, ridge and key weathering details were assessed as requiring comprehensive renewal. The project should include roof coverings, battens, appropriate membrane, lead weatherings, chimney repairs, access and contingency for concealed timber defects.

Subject to completion of the recommended repairs, no reason was identified why the building should not continue to provide many decades of future service. The expenditure should therefore be viewed as a conservation-led investment in the long-term preservation of a significant Grade II listed asset.

03 / KEY RISKS

Principal liabilities identified

Complete re-thatching required

The main water-reed coat and straw ridge are approaching the end of their effective service lives.

Concealed roof structure

No roof void access was available. Timber defects may therefore only become apparent when the existing thatch is stripped.

Defective abutment weatherings

Cement-based flashings are deteriorated and in places direct water towards rather than away from the thatch.

Historic masonry repairs

Open joints, mortar loss and incompatible cementitious repairs require conservation-led masonry work.

Listed building controls

Materials, ridge detailing, leadwork and structural repairs must respect the significance of the Grade II listed building.

Occupation during works

The scale of stripping and roof renewal means continued occupation during the project should not automatically be assumed.

INSPECTION 01 / PRIMARY ROOF COVERING

Water-reed thatched roof

Main roof slopes · Water reed over straw base coat

CR3 · REPLACEMENT WITHIN 1 YEAR

Inspection observations

The principal roof slopes are covered with water-reed thatch laid over an older straw base coat. The covering exhibits widespread age-related weathering, moss growth and erosion. Gullies have formed where rainwater repeatedly follows established paths down the roof surface and horizontal course lines are becoming visible as the reed has weathered back towards its fixings.

Evidence of moisture penetration

Dark staining was identified beneath the eaves in a localised area, providing evidence that moisture has penetrated through the covering further up the roof slope. This supports the wider assessment that the roof is approaching the end of its serviceable life.

Specialist assessment

The specialist thatching inspection concluded that the level of wear had progressed beyond the stage where patch repair to the water-reed coat would provide a durable or economically sensible long-term solution. Strut’s inspection was consistent with this conclusion.

Recommended action

Allow for comprehensive re-thatching using premium quality water reed, together with renewal of the ridge and netting. Once stripped, inspect all exposed battens and structural timbers and undertake repairs where necessary. The wider roofing project should incorporate the associated chimney and abutment works rather than treating these as separate repairs.

ORIGINAL INSPECTION PHOTOGRAPHS
INSPECTION 02 / RIDGE & ROOF FEATURES

Straw ridge and eyebrow dormers

Block-cut ridge · Hazel fixings · Traditional dormer details

CR3 · RIDGE REPLACEMENT REQUIRED

Ridge condition

The traditional block-cut straw ridge has experienced significant weathering and loss of thickness. Deterioration was noted to the hazel spars and fixings, while the reduction in ridge material has created a pronounced gap beneath the galvanised protective netting.

Remaining service life

The ridge was assessed as having reached the end of its effective service life. Localised repair would not provide an appropriate long-term solution and renewal should form part of the complete re-thatching project.

Eyebrow dormers

The front elevation incorporates characteristic eyebrow dormers with brick-built fronts and painted timber windows. The masonry and timber elements appeared generally stable and serviceable, but the surrounding thatch requires renewal. These interfaces should therefore be inspected in detail once the existing covering has been removed.

INSPECTION 03 / WEATHERING DETAILS

Abutments, flashings and chimney stacks

Cement weatherings · Chimney junctions · Adjoining buildings

CR3 · COORDINATED REPLACEMENT

Existing arrangement

The roof incorporates several complex junctions with chimney stacks, adjoining masonry and neighbouring historic buildings. Existing weatherings are predominantly formed in cement mortar rather than traditional lead flashings.

Defects identified

The cement weatherings are heavily deteriorated in places. Poor falls were also identified, with certain details directing water back towards the thatch. This concentrates moisture and contributes to accelerated deterioration and gullying of the adjoining roof covering.

Chimneys

The masonry chimney stacks remain generally stable but require concurrent inspection and repair. Localised repointing, flaunching repairs and attention to chimney pots should be anticipated. Redundant flues should remain appropriately ventilated.

Recommended action

Remove the defective cementitious abutment details as part of the re-thatching project and replace them with appropriately designed Code 6 milled lead flashings and weatherings. Undertake chimney masonry, flaunching and terminal repairs while the access is available.

INSPECTION 04 / HISTORIC FABRIC

Sandstone masonry and pointing

Open joints · Mortar loss · Cementitious repairs

CR2 · CONSERVATION REPAIRS

Inspection observations

The coursed sandstone rubble walls were generally stable and serviceable. Localised open joints, mortar loss, surface weathering and historic stone deterioration were nevertheless identified.

Previous repairs

Different generations of repointing are evident. Some areas contain hard cementitious mortar which is technically incompatible with the traditional solid masonry. Surface-applied pointing to parts of the rear elevation was also loose and friable.

Implications

Open joints permit moisture penetration while hard cement-rich repairs can concentrate evaporation through the softer adjoining stone. Over time this can accelerate localised erosion and decay of the historic masonry.

Recommended action

Undertake targeted masonry conservation including removal of inappropriate cementitious repairs where practicable, repointing of open joints using compatible lime mortar and isolated stone repairs where deterioration warrants intervention.

INSPECTION 05 / ANCILLARY FABRIC

Traditional joinery and outbuildings

Timber windows · External doors · Pantile outbuildings

CR2 · PLANNED MAINTENANCE

Windows and doors

Traditional painted timber casement windows and external doors contribute positively to the character of the listed building. They remained generally serviceable, although localised paint deterioration and weathering require planned maintenance.

Repair rather than replace

Historic joinery should generally be retained wherever practical. Local timber repairs, careful preparation and appropriate breathable decorative finishes are preferable to unnecessary wholesale replacement.

Outbuildings

Two traditional masonry outbuildings remain generally serviceable. Their clay pantile roof coverings require local repair, while the smaller garden store may ultimately require more extensive roof renewal if localised repairs prove uneconomic.

04 / CAPITAL PLANNING

Indicative repair cost summary

The original survey included budget allowances to help the client understand the scale and timing of future expenditure. These are indicative allowances rather than contractor quotations and exclude VAT.

Repair category Indicative range
External masonry repairs £10,000–£15,000
Main roof / comprehensive re-thatching £90,000–£120,000
Abutments & junction details £10,000–£15,000
Windows & external doors £4,500–£6,500
Outbuildings £3,000–£8,000
Total recorded allowance £117,500–£164,500
Year 1 capital forecast

The original report allocates approximately £104,500–£141,500 excluding VAT to Year 1, reflecting the priority given to roof renewal, weathering details and immediate external maintenance.

Budget figures are indicative only and do not constitute quotations. Actual costs depend upon specification, access, statutory requirements, contractor availability and the extent of concealed defects revealed when the existing roof covering is removed.

05 / CONSERVATION-LED SURVEYING

Turning a roof defect into a coordinated conservation project

The value of surveying a historic building lies in understanding how individual repairs interact. Re-thatching this property should not be approached as the isolated replacement of a roof covering.

Specialist inspection

Combine building surveying with specialist trade knowledge where the construction demands expertise beyond a general visual inspection.

Use access intelligently

Once scaffolding and temporary protection are installed, inspect and repair chimneys, abutments, adjoining masonry and concealed roof structure during the same programme.

Preserve significance

Retain traditional construction, historic joinery and compatible materials while replacing elements that have genuinely reached the end of their useful life.

Plan the expenditure

Translate survey findings into a realistic schedule of works, capital forecast and procurement strategy rather than simply presenting a list of defects.

The objective is not merely to put a new thatched roof on the building. It is to use the intervention to secure the historic fabric for the next generation.
06 / SCOPE AND LIMITATIONS

About this example

The original commission comprised a visual and non-destructive inspection of the dwelling, accessible outbuildings, immediate grounds and external building fabric. The thatched roof was assessed with specialist contractor input and supplemented by drone inspection.

No roof void access was available. The concealed roof structure, underside of the thatch, timber framing, insulation and associated hidden components could therefore not be directly inspected. No intrusive opening-up or testing of building services was undertaken.

The eventual condition of concealed roof timbers will only become fully apparent once the existing thatch is removed. A suitable contingency should therefore form part of any future roofing project.

Public demonstration only. This is an edited case-study presentation of a survey inspected on 7 June 2026. It is not the complete commissioned report, does not establish the property’s present condition and must not be relied upon by third parties. Client and tenant information has been omitted.

07 / SPECIALIST SURVEYING

Buying or managing a listed historic building?

Strut Building Surveyors undertakes specialist surveys of listed buildings, thatched cottages, historic estates and complex traditional properties across York and Yorkshire. Where appropriate, we coordinate specialist trade input, drone inspection and conservation advice to establish both the condition of the building and a practical route to repair.

Discuss a historic building survey →   Explore more report examples